Hanna Instruments Model 9829 pHORPECDO Meter with GPS with 10m Cable (76904)

Hanna Instruments® Model 9829 pH/ORP/Conductivity/Dissolved Oxygen Meter with GPS

Type : Meter with 10m Cable , Meter with 4m Cable

ข้อมูลเฉพาะ

  • Brand: Hanna
  • MPN: HI 9829-10101
  • UNSPSC: 41112304

 

Range: Temperature, 23.00°F to 131.00°F (-5.00°C to 55.00°C, 268.15 K to 328.15 K); pH, 0.00 to 14.00 pH; ORP, ±2000.0 mV; Dissolved Oxygen, 0.0 to 500.0%, 0.00 to 50.00 mg/L; Conductivity, 0 to 200 mS/cm (absolute EC up to 400 mS/cm); Resistivity, 0 to 999999 Ω•cm, 0 to 1000.0 kΩ•cm, 0 to 1.0000 MΩ•cm; TDS, 0 to 400000 mg/L or ppm (maximum value depends on the TDS factor); Salinity, 0.00 to 70.00 PSU (extended Practical Salinity Scale); Seawater Sigma, 0.0 to 50.0; Atmospheric Pressure, 450 to 850 mmHg, 17.72 to 33.46 inHg, 600.0 to 1133.2 mbar, 8.702 to 16.436 psi, 0.5921 to 1.1184 atm, 60.00 to 113.32 kPa. Resolution: Temperature, 0.01°F (0.01 °C, 0.01 K); pH, 0.01 pH; ORP, 0.1 mV; Dissolved Oxygen, 0.1%, 0.01 mg/L; Conductivity - Manual, 1 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm, 1 mS/cm; Automatic, 1 µS/cm from 0 to 9999 µS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm; Automatic mS/cm, 0.001 mS/cm from 0.000 to 9.999 mS/cm, 0.01 mS/cm from 10.00 to 99.99 mS/cm, 0.1 mS/cm from 100.0 to 400.0 mS/cm; Resistivity, Depending on resistivity reading; TDS - Manual, 1 mg/L (ppm), 0.001 g/L (ppt), 0.01 g/L (ppt), 0.1 g/L (ppt), 1 g/L (ppt); Automatic, 1 mg/L (ppm) from 0 to 9999 mg/L (ppm), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Automatic g/L (ppt), 0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt), 0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt), 0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt); Salinity, 0.01 PSU; Seawater Sigma, 0.1; Atmospheric Pressure, 0.1 mmHg, 0.01 inHg, 0.1 mbar, 0.001 psi, 0.0001 atm, 0.01 kPa. Accuracy: Temperature, ±0.27°F (±0.15°C, ±0.15 K); pH, ±0.02 pH; ORP, ±1.0 mV; Dissolved Oxygen, 0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater; 300.0 to 500.0%: ±3% of reading 0.00 to 30.00 mg/L: ±1.5% of reading or 0.10 mg/L whichever is greater; 30.00 mg/L to 50.00 mg/L: ±3% of reading; Conductivity, ±1% of reading or ±1 µS/cm whichever is greater; TDS, ±1% of reading or ±1 mg/L (ppm) whichever is greater; Salinity, ±2% of reading or ±0.01 PSU whichever is greater; Seawater Sigma, ±1; Atmospheric Pressure, ±3 mmHg within ±15°C from the temperature during calibration. Temperature Compensation: Automatic from 23°F to 131°F (-5°C to 55°C). Waterproof Protection: Meter, IP67; Probe, IP68. Battery: 4 rechargeable C cell Ni-MH batteries (included) or 4 alkaline C cell batteries (not included). Dimensions: 8.7˝ x 4.5˝ x 2.2˝. Weight: 26.5 oz.

คำอธิบาย

Hanna Instruments Model 9829 pH/ORP/EC/DO Meter with GPS with 10m Cable

Equipped with a built-in GPS receiver and antenna, this multiparameter meter allows you to track measurements from specific locations with detailed coordinate information that can be viewed on the display! Combining a multiparameter probe with field-replaceable sensors, this versatile, waterproof meter measures pH, ORP, conductivity, dissolved oxygen, temperature, resistivity, TDS, salinity, seawater specific gravity, and atmospheric pressure (measured for dissolved oxygen compensation). The meter can also be customized with the addition of ion selective electrodes (ISE) that measure common surface water contaminants. Choose from ammonium, chloride, or nitrate ISE sensors (each sold separately). The microprocessor-based logging probe ensures reliable data collection. The meter’s logging memory holds up to 44,000 records (continuous automatic logging or log-on-demand of all parameters), and measurements are shown on a large, backlit graphical display that also allows for full configuration of each parameter. Data can be plotted on the meter and also downloaded to a PC. The meter features a logging interval range from one second to three hours, Fast Tracker™ Tag Identification System to associate measurements with particular locations where iButtons® have been installed, password protection, GLP (Good Laboratory Practice) feature with the last five calibrations recorded, and USB connectivity. Includes meter, multiparameter probe, calibration solution, calibration beaker, probe maintenance kit, four rechargeable C cell Ni-MH batteries, power adapter with cable, 12V vehicle outlet adapter, five iButtons with holders, USB interface cable, Windows®-compatible software, instruction manual, and rugged carrying case.

Visitors: 115,462